First, the alarm caused by insufficient pressure of the lubrication system of the processing center
1. Manual operation to see if the pressure can meet the requirements, if the pressure shown by the pressure gauge is too low, generally the oil pipe has leaked or the filter screen of the oil pump is too dirty to cause the oil is not smooth, but also check the external filter. Alarm phenomena will also occur when the oil is mixed or the temperature is too low.
2. The equipment parameters are not set appropriately, the set oil interval is too long, and the oil pressure will not go up, and an alarm will appear.
Second, what maintenance work needs to be done in the daily use of the lubrication system of the vertical machining center:
1. Check the status of the lubrication system and pressure gauge in time, clean the filter frequently, replace the lubricating oil, and unclog the oil circuit.
2. Check the gas path system in time, clean the air filter, and avoid the leakage of gas pressure.
3. Clean the oil tank frequently and replace the oil in time. Replace seals when conditions permit.
4. Check and tighten the transmission parts of each part, and replace the defective parts in time.
5. During daily maintenance, check the grease lubrication parts one by one, and fill the grease in time.
6. Ensure the cleanliness of each transmission surface, and carefully clean each transmission surface during maintenance.